Ball-Bar
10 times of area compared with conventional cone tip. Ball shape. Compatible with different sizes of cones. Customized design is available.
Key words:
Classification:
Email:
Ball-Bar
10 times of area compared with conventional cone tip. Ball shape. Compatible with different sizes of cones. Customized design is available.
Test Parameter: Ball-end resistance, sleeve friction, pore water pressure
Test Range: Ball-end resistance 50kN, sleeve friction 10kN, pore water pressure 3.5MPa (can be customized)
Test Accuracy: Ball-end resistance better than 0.5%, sleeve friction better than 1%, pore water pressure better than 0.5%.
Cone: suitable for 2, 5, 10, 15, 20cm² CPT cones
Note: Vacuum degassing and saturation treatment of the sensor is required before the pore water pressure test.
Previous Page
T-Bar
Next Page
Previous Page
Next Page
How can we help?
Peneson Geological Technology Co., Ltd.
Telephone: +86-20 3221 7686
Email: info@peneson.com
Address: Junan Science Park, Xinzhou Road, Xintang Town, Zengcheng District, Guangzhou, Guangdong Province, China
Copyright©2023 Peneson Geological Technology Co., Ltd.
SAF Coolest v1.2 设置面板 IXUSX-APUA-XAAEE-AXS
无数据提示
Sorry, the current column has no content for the time being.!
You can view other columns or returnHome Page