10 times of area compared with conventional cone tip. Cylindrical shape. Compatible with different sizes of cone. Customized design is available.
Key words:
Classification:
Email:
T-Bar
10 times of area compared with conventional cone tip. Cylindrical shape. Compatible with different sizes of cone. Customized design is available.
Test Parameter: T-end resistance, sleeve friction, pore water pressure
Test Range: T-end resistance 50kN, sleeve friction 10kN, pore water pressure 3.5MPa (can be customized)
Test Accuracy: T-end resistance better than 0.5%, sleeve friction better than 1%, pore water pressure better than 0.5%.
Cone: suitable for 2, 5, 10, 15, 20cm² CPT cones
Note: vacuum degassing and saturation treatment of the sensor is required before the pore water pressure test.
Previous Page
Double-bridge Cone
Next Page
Previous Page
Next Page
How can we help?
Peneson Geological Technology Co., Ltd.
Telephone: +86-20 3221 7686
Email: info@peneson.com
Address: Junan Science Park, Xinzhou Road, Xintang Town, Zengcheng District, Guangzhou, Guangdong Province, China